In residential building we are apply the MONOSTRAND SYSTEM  WIHT POST TENSIONING.with this technology slab  thickness will be reduced up to 115mm th, steel qty - it will comes around 6 to 7 kg/m2.

 It will be applicable in grade slabs, tennis courts, residential apartments, villas also.

pls (STRUCTURAL ENGINNERS,ARCHITECTS,CLIENTS)give your comments, consider PT  in your projects to reduce the OVERALL COST.

 

 Top Comment : Subhendu Roy   | 02 24 2009 10:13:23 +0000
There are various reason why we should consider post tensioning because of design flexibility, joints in structure can be minimized and it can improve improve the long-term durability of concrete structures exposed to aggressive environments. So its better to consider PT in all of our projects to reduce the overall cost.
 
2 comments on "Post tensioning system in residential building construction"
  Commented by  Paul F. Rastellini, Superintendent, unemployed    | 02 28 2009 20:15:02 +0000
Rating : +1 
I agree. I have supervised PT, Steel and Concrete in the US for the last 15 years. How about a job?
  Commented by  Subhendu Roy, Construction-Heavy, DLF    | 02 24 2009 10:13:23 +0000
Rating : +1 
There are various reason why we should consider post tensioning because of design flexibility, joints in structure can be minimized and it can improve improve the long-term durability of concrete structures exposed to aggressive environments. So its better to consider PT in all of our projects to reduce the overall cost.
Add your comment on "Post tensioning system in residential building construction"

Rate:
Submit
Leading Recruitment Firm
  • Create a confidential Career Profile and Resume/C.V. online
  • Get advice for planning their career and for marketing of experience and skills
  • Maximize awareness of and access to the best career opportunities
Viewers also viewed
1. Get up 15 minutes earlier 2. Prepare for the morning the night before 3. Avoid tight fitting...
 
21 referals 13 answers, 469 views
Load Bearing Construction vs RCC frame construction
 
166 referals 36 arguments, 12034 views
Steel shuttering is a better option or wooden shuttering for civil engieering constrution...
 
177 referals 48 arguments, 2932 views
more...  
Recent Knowledge (70)
  A day after he resigned, Santosh Sarode (31), a software engineer, allegedly strangled his...
1600 referals 32 comments, 1538 views
I am not sure whether this is really happened or not, But I liked it and want to share with all...
 
63 referals 8 comments, 198 views
Why China And India Don't Get Along January 4, 2011: India-China ties are set to enter...
 
98 referals 3 comments, 108 views
more...  
More From Author
hello sir in Post tensioning generally we are using HIGH TENSILE STRAND(HT Strand).it is available in 12.7mm ,15.2 mm dia(0.5" or 0.6").its ultimate tensile force is 12.7mm=1860m/mm2,15.2mm=2120n/mm2.IS 14268 CODE. for any information pls send mail....
yes i also agree, its diffently because of management.
In residential building we are apply the MONOSTRAND SYSTEM  WIHT POST TENSIONING.with this technology slab  thickness will be reduced up to 115mm th, steel qty - it will comes around 6 to 7 kg/m2.  It will be applicable in grade slabs, tennis...
more...